Every open pond on a generating site is losing water to the air and growing algae that end up in your filters and exchangers. Covex® floating cover seals 98% of the surface, cuts evaporation by up to 97% and algae growth by over 90%. No structures, no anchoring, no draining the pond.
A generating site runs on water as much as on fuel or sunlight: cooling circuits, raw water storage, demineralization feed, panel wash water, digester and digestate storage. All of it sits in open ponds, and an open pond in a warm, windy or arid location can lose several meters of depth a year to the air alone. The water does not disappear from the balance sheet: it comes back as purchase, treatment, pumping and, increasingly, as a limit written into your water permit.

Replacing what evaporates means buying, trucking or pumping more water, and treating it before it enters the circuit. Where the resource is allocated by permit, the ceiling arrives before the cost does.
Sunlight on a nutrient-rich pond grows algae that block strainers and filters, foul heat exchanger surfaces, shift pH and force extra dosing. The cost shows up as maintenance hours, not as a water bill.
Evaporation is the dominant heat loss on a warm open pond. Where the liquid is meant to stay warm, such as digester feed or process water, that heat has to be put back in with fuel or electricity.
Covex® is a modular cover of hexagonal HDPE units that float and interlock on their own. It covers 98% of the surface in a stable, permanent way thanks to its aerodynamic design, its factory-sealed water ballast and its minimal freeboard.
Evaporation is not a single number, it is the result of your climate, your pond geometry and your operating regime. We run a full energy balance on the water surface using an in-house simulation tool built on TRNSYS, fed with the meteorological file for your coordinates, and return the water your site loses today and what it keeps with the cover on.
The output is cubic meters a year for your pond, not a percentage from a brochure.
Results depend on climate, pond geometry, coverage achieved and operating regime. Every Covex® project is sized on your site data.
Send us your pond area and coordinates and we will model what it loses today.
Model my pond
Intakes, pumps, aerators, level sensors and walkways stay where they are. Units float freely around fixed equipment and we plan the access zones your operators need to keep clear.
Demand, rainfall and plant load move the pond level every week. The cover rises and falls with it and re-levels by itself, with no cables, anchors or tensioning.
Rainfall drains between units into the pond, so you keep the catchment. No standing water on top, no rainwater pumps, no sheet sagging under its weight.
Generating sites sit on open terrain. Covex® XT50 is designed for winds up to 100 km/h, thanks to its aerodynamic profile and low freeboard.
By removing the evaporative loss at the surface, the cover slows the cooling of warm liquids. Where the process needs the heat, that is auxiliary energy you do not have to spend putting it back.
The same insulating effect works in the other direction. In cold climates the cover delays the formation of surface ice and the operating problems that come with it.
Cooling pond, raw water reservoir or wash water pond? Tell us about the site and we will size a cover for it.
Talk to a specialist| Covex® | Floating membrane | Shade structure | Floating solar | |
|---|---|---|---|---|
| Cuts evaporation | Up to 97% | High | Partial, shade only | Partial, panel footprint only |
| Controls algae | Over 90% | Yes | Partial | Partial |
| Energy or chemicals in operation | None | Rainwater pumping | None | Generates power |
| Pond drained to install | No | Often | Usually | No |
| Level changes | Self-levelling | Needs ballast and slack design | Fixed structure | Anchored, with slack |
| Rainwater | Passes through | Must be pumped off | Passes through | Passes through |
| Equipment on the pond | Units float around it | Needs penetrations | Needs clearance | Needs layout design |
| If something fails | One unit, replaced by hand | A tear affects the sheet | Structural repair | Specialist intervention |
Typical characteristics of each technology; specific products vary. If your goal is to generate power on the water, floating solar is the right tool. If your goal is to keep the water and stop the algae with no operating cost, Covex® is.
Comparing options for your site? We will put together a side-by-side for your pond.
Get my comparisonPond area and geometry, coordinates, equipment on the surface, operating levels and wind exposure.
Energy balance on your meteorological file, then sizing at 50 units per square meter, shipped in bulk bags straight to site.
Units are released from the bank and spread and interlock on their own. No draining, welding or anchoring, and no plant outage.
Periodic visual inspection only. At the end of its life, the cover is fully recyclable.
It depends on what the pond is for. On a pond whose job is to reject heat, covering it works against you and we will say so. On storage, raw water, makeup and wash water ponds, where the water is an asset rather than a heat sink, the cover keeps the volume and the quality. We review the duty of each pond before quoting.
Yes. Panel wash water and raw water ponds at solar plants are a direct fit: they sit in high-radiation, often arid locations, they are normally calm, and the water quality matters for the panels. The cover goes on without touching the array.
Covex® is best suited to storage, equalization and holding ponds. Where there are surface aerators or strong turbulence, we evaluate the layout case by case and may cover only part of the surface.
That is what the model is for. We run the energy balance on your coordinates and your pond, and the answer comes back in cubic meters a year. Up to 97% is the upper range of the reduction in evaporation; your site may sit below it depending on climate and coverage achieved.
Covex® XT50 is designed for winds up to 100 km/h. In strong gusts some units may stack temporarily, but floating units do not blow away and the cover re-levels by itself. Units left on the slope when the level is very low are the most exposed, so we review your operating levels as part of the study.
HDPE has broad chemical resistance and is the standard material for liners and water infrastructure. For water with unusual chemistry, biocide dosing or high temperature, we review your analysis before quoting. Operating range is -40°C to 85°C.
Tell us the pond area and where the site is. A Covex® specialist will come back with the water your pond loses today, a sizing and a quote.
Material written for plant and engineering teams, not for procurement brochures.
Technical articles on what drives evaporation on an open surface, why algae return after every treatment, and how floating covers change both.
Send us the pond area, its coordinates and the equipment on the surface, and we return the water it loses today, a sizing and a quote.
Evaporation, algae, heat loss and odor all come from one place: the open liquid surface.
A 1,760 m² irrigation reservoir in Napa, California. The units are tipped straight into the water from the bank and spread and interlock by flotation. No civil works, no anchoring, and the reservoir is never drained. The method is the same on a cooling, raw water or wash water pond.